Chat with us, powered by LiveChat

TABLEX™ FOR EX are EXIT signs used where safety and notifications are needed in explosion proof location applications

Case studies

Benefits:

  • Two adjustable high-lumen spotlights
  • Independent battery backup system for exit signs and spotlights
  • Unit can power up to two optional remote spotlights
  • Field-replaceable LED circuit boards and drivers with quick disconnects
  • Emergency battery backup integral to sign (no additional enclosure required)
  • Edge-lit sign

Specification

BODYA360 aluminum (less than .4% copper content) with baked-on gray epoxy finish
GASKETOne-piece neoprene
SIGNAcrylic
HARDWAREStainless steel
 TOTAL LUMENS PER HEAD420.78 LM
OUTPUT WATTS PER HEAD4.83 W
EFFICACY (LUMENS/WATTS)87.12
CRI72
CCT5 672 K
DIMENSIONS19.75 x 5.63 x 23.88 IN
(501.65 x 143.00 x 606.55 MM)
WEIGHT
40.5 LBS
MOUNTING
Wall, pendant and end mounting options
OPTICS
Wide and narrow-beam optics available
LED OPTIONSRed and Green
AMBIENT TEMPERATURE10˚C TO 35˚C (GREEN)
10˚C TO 45˚C (RED)
T-RATING T6

Step 1 create your own

Ordering Information:

Part number example: PRO-HL-SB-PPC-RV-120-5K-60W-S

Family name
TAB
Enclosure type
EX
Mounting
MO
Number of faces
0
1
2
Installed heads
0
1
2
Remote heads
0
1
2
3
4
Legend color
N
R
G
Optics
N
W
Body color
S
-
+
+

Ordering details

Enclosure type

EX
Explosion Proof Rated Body

Mounting

MO
Wall, pendant and end mounting options

Number of faces

0
None
1
Single
2
Double

Installed heads

0
None
1
One
2
Two

Remote heads

0
None
1
One
2
Two
3
Three
4
Four

Legend color

N
None (For 0 faces)
R
Red
G
Green

Optics

N
Narrow
W
Wide

Body color

S
Silver (Standard)
Combintations Available
InstalledRemoteDrivers
201
111
021
222
132
042

Applications

  • Waste Water Treatment
  • Oil and Gas Refining
  • Hazardous Locations
  • Hazardous Storage
  • Marine, Engine and Battery Rooms
  • Manufacturing Facilities

Documents

Compliance & certification

ETL/CETL Certified to:

UL 844 Hazardous Locations
UL 1598A Marine Outside Type
UL 1598 Wet Locations
UL 8750 LED Safety
UL 924 Emergency Lighting
CUL
IP65
NEMA 4X
Patent No. 7,287,347
Other Patents Pending
USCG Regulation 46 CFR Subparts 111.75-15(e) & 112.43

Approved for:

Class I, Division 1, Groups C & D
Class II, Division 1, Groups E, F & G
Class III
Class I, Zone 1, Groups IIA, IIB

Start typing and press Enter to search